8 zone inputs for intrusion detection. 4 zones configurable as PGM outputs. 1 AUX power output for detectors Built-in bus extender for extended bus range. Compatible with wide range of 3rd party wired detectors.
Power supply - general: - Input voltage: 12 VDC norminal (9~16 VDC), powered by bus. - Quiescent current: 80 mA @12VDC. - Max. current: 150 mA @12VDC.
Power supply - auxiliary power output: - Output capacity: 12VDC norminal (9~16 VDC), 500mA. - Output protection: 500 mA PPTC.
PGM output: - Output voltage: 0 VDC with switched (NPN output). - Max. current: 200 mA per output.
Operating temperature: -10°C to 50°C, indoor use only. Storage temperature: -20°C to 60°C. Relative humidity: 10% ~ 90% non-condensing. Dimension: 110 x 155 x 31 mm / 225 g. Tamper-proof: Front and Rear. Installation method: Wall mount.
Compliance: Electrical conformity: CE, CB EN 50131: Security Grade 2, Environmental Class II
64 zones and 64 outputs.32 areas.1 installer, 1 admin, 100 operators.Dual bus, up to 32 bus devices per bus.Dual-path notification to ARC, support ARC..
128 zones and 128 outputs.64 areas.1 installer, 1 admin, 128 operators.Dual bus, up to 64 bus devices per bus.Dual-path notification to ARC, support A..